Helena catalog

Cascade® M and Cascade® M-4
Manual Coagulation Analyzers


Cat. No. Item
1710 Cascade M,  2-channel analyzer, 4-line screen, 110V/220V
1711 Cascade M-4,  4-channel analyzer, 6-line screen, 110V/220V
1194 Comprehensive Replacement Agreement for Cascade M
1195 Comprehensive Replacement Agreement for Cascade M-4
9164 Service Manual for Cascade M
9167 Service Manual for Cascade M-4

Cascade M and Cascade M-4 are manual hemostasis analyzers that are ideal for all routine clotting assays - PTs, aPTTs, thrombins, fibrinogens and factor assays. Designed for easy, inexpensive, low-volume testing, these analyzers are small in size but big on features, offering you many time and labor saving benefits. Operation is simple and economical.

Easy-to-Use Keypad, On-Screen Prompts - All tests are clearly enumerated on the keypad for fast, easy test selection - there's no guess work caused by "hidden" function keys. Computer prompts appear on the screen to conveniently step the user through testing. Default settings are preprogrammed but can easily be changed, if desired. (Instructions for changing parameters are provided).

State-of-the-Art Photo Optics - Independent photo-optic detection sources (two for Cascade M, four for Cascade M-4) read all samples, regardless of turbidity. Samples can be read in duplicate or in single.

Computerized Features, On-board Quality Control - Cascade M and M-4 store standard curves, calculate patient results, INRs and aPTT ratios. Quality control tasks are easy because Cascade M and M-4 can calculate mean, SD and CV, plus plot and print Levy-Jennings QC charts.

Compact, Lightweight - With benchtop footprints smaller than 15" wide by 15" deep and weights of approximately 20 pounds, Cascade M and M-4 are sized to fit any lab. Compact size, dependability and versatility make Cascade M and M-4 excellent choices as primary analyzers for smaller laboratories or as backup units for larger coagulation analyzers.

Cascade M & Cascade M-4 Specifications

Tests: PT, aPTT, Fibrinogen, Thrombin Clotting Time, Factor Assays.

Sample Size: 50 μL, 100 μL, 200 μL.

Optics System: Constant current LED photo optic detection.

Channels: 2 for Cascade M; 4 for Cascade M-4.

Temperature Control: 37°C ± 0.5°C.

Special Features: Stores standard curves; calculates final results for fibrinogens and factor assays. Calculates INRs and aPTT ratios. On-screen prompts for test instructions. LIS interfacing (Cascade M-4).

Quality Control Features: Calculates mean, SD, and CV. Plots Levy-Jennings charts.

Display: Fluorescent LCD. Cascade M: 4 lines x 40 characters. Cascade M-4: 6 lines x 40 characters.

Printer: Accommodates 4 1/2" thermal paper. Reports include date, time, INR, average, technician and patient ID. Prints QC and standard curves.

Power Requirements: 110/220 Vac, 50/60 Hz, 100 Watts max.

Operating Environment: Room temperature.

Dimensions: Cascade M: 8" H x 15" W x 14" D (20 cm H x 38 cm W x 35 cm D).

Cascade M-4: 8 1/2" H x 14" W x 13" D (22 cm H x 35 cm W x 33 cm D).

Weight: Cascade M: 20 lbs. (9 kg). Cascade M-4: 21 lbs. (9.5 kg).


Cascade M & Cascade M-4 Accessories

Cat. No.

Item

1718

Cascade M / M-4 Cuvettes, 5 x 100/pkg

1720

Cascade M / M-4 Printer Paper, 5 rolls

1475

Disposable Pipette Tips (50-200 µL), 1000/pkg


Previous | Next | Catalog Products Index | Alphabetical Product Listing
Numerical Product Listing | Reply Card | Home