ICHOR® Hematology Analyzer
The ICHOR hematology instrument is a self-contained, compact, easy-to-use, automated impedance cell counter. When used with Plateletworks reagents, the ICHOR system provides a hematology profile of a standard CBC with platelet count plus platelet aggregation or inhibition within five minutes. The test is simple. A fresh whole blood sample is added to both an EDTA baseline and a Collagen, ADP or Arachidonic Acid agonist tube. All tubes are run on the Ichor hematology analyzer. CBC, including platelet count, is available within minutes. Platelet aggregation is then calculated from results.
• CBC & Platelet Aggregation at Point of Care - provides immediate platelet count and aggregation, WBC, RBC, hemoglobin and hematocrit, RBC indices (MCV, MCH, MCHC), RBC, MPV and platelet histograms
Tests: Hemoglobin, Hematocrit, RBC Count, RBC Indices (MCV, MCH, MCHC), WBC Count, Platelet Count, MVP, Whole Blood Platelet Aggregation with ADP, Collagen, Arachidonic Acid Reagent Delivery System: All-in-one reagent/waste pack contains reagent and self-included waste chamber Linearity: RBC (x106 cells/µL): 0.2 to 7.5 ±0.05 (or ±3%) WBC (x103 cells/µL): 0.5 to 80 ±0.2 (or ±3%) Hemoglobin (g/dL): 2.5 to 23 ±0.3 (or ±2%) Platelets (x103 cells/µL): 10 to 1,000 ±10 (or ±6%) Sample: Automated, closed-tube sampling requires only 10-12 µL of whole blood Throughput: 70 seconds per sample; 60 samples per hour Operating Mode: Sequential, single channel analysis Operating Principle: Electronic impedance measurement Special Features: Programmable high and low limits for each parameter. Programmable automatic cleaning cycle. Push button “standby” and “shut down” cycle. Calibration SmartCard for automatic instrument calibration. Quality Control Features: Integrated QC program for data management and automatic report generation. User Interface: Alphanumeric keypad Display: 2 x 40 character backlit LCD Printer: 4.5" (112 mm) thermal. (Dot matrix option also available.) Printout: Includes test results, RBC and platelet histograms (if desired), high and low limit indications, alphanumeric patient identification, operator ID, time and date. Memory: Stores last result in memory. Optional Memory SmartCards archive up to 60 patient data points per card. Power Requirements: 90 to 240 Vac (self-adjusting), 50/60 Hz Operating Environment: Room temperature Dimensions: 16.5"H x 12.5"W x 14"D (42 x 32 x 36 cm) Weight: 30.8 lbs. (14 kgs) |
Previous | Next
| Catalog Products Index | Alphabetical
Product Listing
Numerical Product Listing |
Reply Card | Home